Opendata, web and dolomites

MagnetoVirology SIGNED

Diamond Magnetometry: A Versatile Tool for Virology and Medicine

Total Cost €

0

EC-Contrib. €

0

Partnership

0

Views

0

 MagnetoVirology project word cloud

Explore the words cloud of the MagnetoVirology project. It provides you a very rough idea of what is the project "MagnetoVirology" about.

infection    horizon    collaborative    detection    virology    synovial    nmbp    detrimental    magnetometry    limitations    reactive    fr    fnds    underscored    arthritis    centers    point    biotechnology    nanodiamonds    claim    outcome    drug    time    clinical    conclude    radicals    sinv    elucidated    complicated    small    usefulness    vacancy    cellular    host    model    measuring    fundamental    2020    fluorescent    deeper    probe    dt    inside    mediating    health    animal    successful    pharmaceutical    aligns    technique    diagnostics    spatiotemporal    bhc    detecting    free    viral    intend    resolution    fluid    volume    demonstrating    therapy    opposite    sindbis    exact    nanotechnology    t1    kinetics    cells    unparalleled    completion    cell    pathogenesis    infections    industry    anti    oxidants    relaxation    highlight    depends    possibility    sc1    oxygen    sensitivity    interdisciplinary    biology    programs    species    potentially    nitrogen    quantified    toward    patients    interplay    diamond    ros    virus   

Project "MagnetoVirology" data sheet

The following table provides information about the project.

Coordinator
ACADEMISCH ZIEKENHUIS GRONINGEN 

Organization address
address: HANZEPLEIN 1
city: GRONINGEN
postcode: 9713 GZ
website: www.umcg.nl

contact info
title: n.a.
name: n.a.
surname: n.a.
function: n.a.
email: n.a.
telephone: n.a.
fax: n.a.

 Coordinator Country Netherlands [NL]
 Total cost 187˙572 €
 EC max contribution 187˙572 € (100%)
 Programme 1. H2020-EU.1.3.2. (Nurturing excellence by means of cross-border and cross-sector mobility)
 Code Call H2020-MSCA-IF-2018
 Funding Scheme MSCA-IF-EF-ST
 Starting year 2019
 Duration (year-month-day) from 2019-07-01   to  2021-06-30

 Partnership

Take a look of project's partnership.

# participants  country  role  EC contrib. [€] 
1    ACADEMISCH ZIEKENHUIS GRONINGEN NL (GRONINGEN) coordinator 187˙572.00

Map

 Project objective

Reactive Oxygen Species (ROS)/ free radicals (FR) in cells have a very complicated role in viral infections. While some researchers point toward their usefulness in mediating viral infections, others conclude the exact opposite and claim that there are detrimental effects. To probe deeper into virus pathogenesis and improve anti-viral therapy, cellular FR - viral infection kinetics which potentially depends on virus, cell/animal model, type of reactive species, etc. needs to be investigated with high spatiotemporal resolution. However, all the traditional methods capable of detecting FR have limitations when real-time, long-duration, high resolution measurements are to be conducted within a small sample volume (inside of a cell). Recently, diamond magnetometry was proposed to study cellular FR with unparalleled sensitivity, resolution, and the possibility of real-time long-duration measurements. In this highly interdisciplinary collaborative research, I aim to establish this technique in studying cellular FR- viral infections kinetics. As a model system I will investigate the host cell FR response upon Sindbis virus (SINV) infection with high spatiotemporal resolution. FR response will be quantified via measuring T1 relaxation time of Nitrogen Vacancy centers in fluorescent nanodiamonds (FNDs). Furthermore, I intend to highlight the potential of diamond magnetometry in clinical diagnostics and drug development by demonstrating the FR detection in synovial fluid of arthritis patients (outcome of SINV infection) and detecting cells’ FR response to anti- oxidants. Upon successful completion, I will not only have elucidated the interplay of FR and SINV infections but also underscored the potential of diamond magnetometry in fundamental virology, infection biology, clinical diagnostics and pharmaceutical industry. This research strongly aligns with two work programs within Horizon 2020 focused on health (SC1-BHC) and nanotechnology- biotechnology (DT-NMBP).

Are you the coordinator (or a participant) of this project? Plaese send me more information about the "MAGNETOVIROLOGY" project.

For instance: the website url (it has not provided by EU-opendata yet), the logo, a more detailed description of the project (in plain text as a rtf file or a word file), some pictures (as picture files, not embedded into any word file), twitter account, linkedin page, etc.

Send me an  email (fabio@fabiodisconzi.com) and I put them in your project's page as son as possible.

Thanks. And then put a link of this page into your project's website.

The information about "MAGNETOVIROLOGY" are provided by the European Opendata Portal: CORDIS opendata.

More projects from the same programme (H2020-EU.1.3.2.)

ASIQS (2019)

Antiferromagnetic spintronics investigated by quantum sensing techniques

Read More  

AsymmFlow (2020)

Go with the continuous flow: Asymmetric Synthesis of Bioactive Alkaloids by Multistep Continuous-Flow Processes

Read More  

UMMs (2019)

Unifying Monitoring Models of Verbal Monitoring.

Read More