INTELSENS

Integrated Laser Sensor for Exhaled Anaesthetic Agent Monitoring

 Coordinatore THE CHANCELLOR, MASTERS AND SCHOLARS OF THE UNIVERSITY OF CAMBRIDGE 

 Organization address address: The Old Schools, Trinity Lane
city: CAMBRIDGE
postcode: CB2 1TN

contact info
Titolo: Ms.
Nome: Dawn
Cognome: Barker
Email: send email
Telefono: -334722
Fax: -334167

 Nazionalità Coordinatore United Kingdom [UK]
 Totale costo 178˙874 €
 EC contributo 178˙874 €
 Programma FP7-PEOPLE
Specific programme "People" implementing the Seventh Framework Programme of the European Community for research, technological development and demonstration activities (2007 to 2013)
 Code Call FP7-PEOPLE-2007-2-1-IEF
 Funding Scheme MC-IEF
 Anno di inizio 2008
 Periodo (anno-mese-giorno) 2008-06-01   -   2010-05-31

 Partecipanti

# participant  country  role  EC contrib. [€] 
1    THE CHANCELLOR, MASTERS AND SCHOLARS OF THE UNIVERSITY OF CAMBRIDGE

 Organization address address: The Old Schools, Trinity Lane
city: CAMBRIDGE
postcode: CB2 1TN

contact info
Titolo: Ms.
Nome: Dawn
Cognome: Barker
Email: send email
Telefono: -334722
Fax: -334167

UK (CAMBRIDGE) coordinator 0.00

Mappa


 Word cloud

Esplora la "nuvola delle parole (Word Cloud) per avere un'idea di massima del progetto.

engineers    commercial    anaesthesia    uk    monitoring    cambridge    online    stream    professionals    techniques    trace    monitor    patient    anaesthetics    levels    effectiveness    administration    drug    blood    gas    he    background    propofol    dramatically    detection    quality    manufacturers    patients    university    sensor    team    surgery    ultraviolet    pas    exist    times    sensing    exhaled    physicists    impact    medical    induced    acute    tailoring    breath    photoacoustic    applicant    recovery    anaesthetic    dosage    industrial    technique    clinical    concentrations    optical    chemical   

 Obiettivo del progetto (Objective)

'The application of a novel ultra-sensitive photoacoustic gas sensor is proposed to allow for online monitoring of an intravenously administered anaesthetic agent, which is exhaled at trace levels with the patient’s breath during surgery. We respond to a real and acute need for clinical online monitoring of anaesthetic concentrations in the patient’s blood stream during surgery. In the drafting of this proposal, the Applicant, himself from a physical sciences background, has extensively consulted with Prof. T. Absalom and Dr. D Wheeler, Division of Anaesthesia, School of Clinical Medicine, University of Cambridge, UK to define the clinical problem at the core of this application. The project focuses on the monitoring of propofol, one of the most widely used intravenous anaesthetics in general anaesthesia. Currently the effectiveness of propofol induced anaesthesia is only assessed symptomatically, based on highly subjective and unsophisticated scoring. A viable online capability to monitor exhaled trace levels of propofol in patients does not currently exist but would dramatically improve the level of control over its administration. It would both improve the quality of anaesthetic management by tailoring dosage to the individuals’ needs, reduce clinical recovery times and patient aftercare with associated cost benefits. The project is based on a unique interdisciplinary ensemble of physicists, chemical engineers, medical professionals and potential commercial manufacturers focusing on a high impact engineering challenge. The Applicant has an excellent academic background. He has already gained international recognition in terms of invited conference contributions. He has been one of the key players to develop the proposed sensor technology. The proposed high impact project in a multidisciplinary environment at the University of Cambridge, UK, would fully qualify the Applicant for an independent research post at an internationally recognised research institution.'

Introduzione (Teaser)

A novel technique of measuring a common anaesthetic drug in the breath under surgery will help doctors gauge dosage and avoid complications.

Descrizione progetto (Article)

General anaesthesia is very often necessary before surgical operations, but it remains a tricky component of surgery that must be monitored closely. There is an acute need to monitor anaesthetic concentrations in the patient's blood stream during surgery.

The Intelsens project, fully funded by the EU, set out to develop a new way to monitor the patient's levels of propofol, one of the most common anaesthetics. The project is proposing a gas sensor to identify trace levels of the anaesthetic in the patient's breath.

Currently, the effectiveness of propofol-induced anaesthesia is only assessed according to symptoms presented by the patient. The ability to monitor exhaled trace levels of propofol in patients does not currently exist but would dramatically improve the level of control over its administration.

The project team succeeded in developing a new optical sensing concept to trace levels of propofol in the breath. This is expected to improve healthcare quality by tailoring dosage to individual needs, while reducing clinical recovery times and postoperative care, along with associated costs.

Upon injection, propofol is transported into the blood stream and traces of the drug appear in the exhaled breath. In medical feasibility studies using mass spectrometry and gas chromatography the volume of propofol in parts-per-billion had previously been estimated but the techniques were unsuitable for surgery.

After many tests using ultraviolet and infrared rays to measure propofol, the team elaborated the most optimum strategy for optical detection of the drug. The technology relied on what is known as photoacoustic spectroscopy (PAS), built to measure ultraviolet absorption. Laser excitation was also used in the process, and successful equipment was ultimately developed and fine-tuned.

The project proved the concept beyond doubt and was accomplished through active collaboration between physicists, chemical engineers, medical professionals and commercial medical systems developers.The results have raised interest in other research institutes and industrial systems manufacturers.

A follow-up project is aimed at a clinical evaluation of the PAS technique for online propofol monitoring in patients undergoing surgery. The novel techniques have also shown great potential beyond the current application in fields such as atmospheric trace gas sensing, exhaled breath disease diagnostics, industrial process monitoring as well as pollutant detection in the liquid phase.

Altri progetti dello stesso programma (FP7-PEOPLE)

ACETO-SAGATAC-HUMAN (2011)

Comprehensive and systematic study of the acetylation function of acetyltransferases in human cells

Read More  

HG-197 MEHG ASSESS (2009)

Evaluation of Methyl-mercury production and decomposition by using Hg-197 radiotracer produced out of mercury enriched in Hg-196 isotope

Read More  

HR-MOB (2008)

Croatian Researchers' Mobility Network

Read More