Opendata, web and dolomites

MicroMOUPE SIGNED

Microscopy - Making optimal use of photons and electrons

Total Cost €

0

EC-Contrib. €

0

Partnership

0

Views

0

 MicroMOUPE project word cloud

Explore the words cloud of the MicroMOUPE project. It provides you a very rough idea of what is the project "MicroMOUPE" about.

scattered    quadratic    aberration    detection    metal    multiple    creation    noise    proteins    evading    intense    imaging    cavities    fast    designed    vienna    nanometric    electro    interact    electron    introducing    experiment    free    enhancement    optimize    plate    self    landscapes    spatial    molecules    stanford    feasible    sub    interactions    zernike    realized    correction    single    dark    laser    overcoming    modern    shape    resolution    tool    cells    demonstrated    tested    particle    sensitivity    blanking    microscope    pass    sensitive    arbitrary    linear    proof    university    nanoparticles    pulses    pattern    specimens    signal    potentials    post    electrons    switch    specimen    microscopy    fundamental    of    generator    limit    beam    optimal    optics    microscopes    created    optically    optical    photons    accuracy    limits    shot    coherent    limited    bright    times    technologically    adaptive    temporal    particles    dna    probe    ponderomotive   

Project "MicroMOUPE" data sheet

The following table provides information about the project.

Coordinator
UNIVERSITAT WIEN 

Organization address
address: UNIVERSITATSRING 1
city: WIEN
postcode: 1010
website: www.univie.ac.at

contact info
title: n.a.
name: n.a.
surname: n.a.
function: n.a.
email: n.a.
telephone: n.a.
fax: n.a.

 Coordinator Country Austria [AT]
 Project website https://imaging.univie.ac.at/
 Total cost 1˙672˙752 €
 EC max contribution 1˙672˙752 € (100%)
 Programme 1. H2020-EU.1.1. (EXCELLENT SCIENCE - European Research Council (ERC))
 Code Call ERC-2017-STG
 Funding Scheme ERC-STG
 Starting year 2018
 Duration (year-month-day) from 2018-03-01   to  2023-02-28

 Partnership

Take a look of project's partnership.

# participants  country  role  EC contrib. [€] 
1    UNIVERSITAT WIEN AT (WIEN) coordinator 1˙672˙752.00

Map

 Project objective

The sensitivity of modern microscopy is limited by shot-noise. It limits the accuracy of measurements of specimen properties as well as the spatial resolution of electron microscopes when imaging sensitive specimens, such as proteins or DNA. But the shot-noise limit is not a fundamental limit. A technologically feasible and optimal approach to overcoming the shot-noise limit is to have each probe particle interact with the specimen multiple times. We recently introduced this concept to microscopy using self-imaging cavities. Within this project, I want to demonstrate post-selection free sub-shot noise microscopy with both photons and electrons. Optically this will be possible by introducing a fast electro-optical switch into a multi-pass microscope, evading the need for temporal post-selection. After this proof-of principle experiment, the sensitivity enhancement offered by multi-pass microscopy shall be applied to the detection of nanometric particles, such as single molecules, proteins and metal nanoparticles. Linear signal enhancement with the number of interactions is expected for bright-field microscopy. For dark-field microscopy a quadratic enhancement is expected, due to coherent build-up of scattered fields. Finally, adaptive optics will be used to optimize multi-pass microscopy for the study of cells. Multi-pass electron microscopy will be realized in collaboration with Stanford University. It will require several novel electron optical elements that will be designed and tested both at Stanford University and at the University of Vienna. One of these elements will be a pattern generator for electrons based on ponderomotive potentials. The required potential landscapes will be created using adaptive optics to shape intense laser pulses. With this novel electron optics tool fast beam-blanking, a phase plate for Zernike phase microscopy, arbitrary pattern creation and aberration correction will be demonstrated.

Are you the coordinator (or a participant) of this project? Plaese send me more information about the "MICROMOUPE" project.

For instance: the website url (it has not provided by EU-opendata yet), the logo, a more detailed description of the project (in plain text as a rtf file or a word file), some pictures (as picture files, not embedded into any word file), twitter account, linkedin page, etc.

Send me an  email (fabio@fabiodisconzi.com) and I put them in your project's page as son as possible.

Thanks. And then put a link of this page into your project's website.

The information about "MICROMOUPE" are provided by the European Opendata Portal: CORDIS opendata.

More projects from the same programme (H2020-EU.1.1.)

PonD (2019)

Particles-on-Demand for Multiscale Fluid Dynamics

Read More  

Growth regulation (2019)

The wide-spread bacterial toxin delivery systems and their role in multicellularity

Read More  

Regen-membrane (2019)

Pulsed Electrophoretic Deposition to give Membranes for Regenerative Medicine

Read More