Opendata, web and dolomites

BinCola SIGNED

Evaluation of the Benefits of innovative Concepts of laminar nacelle and HTP installed on a business jet configuration

Total Cost €

0

EC-Contrib. €

0

Partnership

0

Views

0

Project "BinCola" data sheet

The following table provides information about the project.

Coordinator
EUROPEAN TRANSONIC WINDTUNNEL GMBH 

Organization address
address: ERNST MACH STRASSE
city: KOLN
postcode: 51147
website: www.etw.de

contact info
title: n.a.
name: n.a.
surname: n.a.
function: n.a.
email: n.a.
telephone: n.a.
fax: n.a.

 Coordinator Country Germany [DE]
 Total cost 1˙555˙576 €
 EC max contribution 1˙555˙576 € (100%)
 Programme 1. H2020-EU.3.4.5.4. (ITD Airframe)
 Code Call H2020-CS2-CFP07-2017-02
 Funding Scheme CS2-RIA
 Starting year 2018
 Duration (year-month-day) from 2018-11-01   to  2020-02-29

 Partnership

Take a look of project's partnership.

# participants  country  role  EC contrib. [€] 
1    EUROPEAN TRANSONIC WINDTUNNEL GMBH DE (KOLN) coordinator 1˙217˙562.00
2    DEHARDE GMBH DE (VAREL) participant 238˙013.00
3    LASERLINE GESELLSCHAFT FUR ENTWICKLUNG UND VERTRIEB VON DIODENLASERN GMBH DE (MULHEIM KARLICH) participant 100˙000.00

Map

 Project objective

The global target of the project “BinCola” is the experimental verification of benefits coming along with the replacement of classically designed nacelles and HTP by enhanced components specifically developed for natural laminar flow (NLF) development. To ensure a realistic evaluation and assessment of benefits relevant wind tunnel tests will be performed at flight Mach and Reynolds numbers. An existing basic model of a business jet configuration will be made available by the Topic Manager and serve as the reference configuration. He is also responsible for the provision of the laminar design of the components to be replaced while their detailed design, manufacturing and assembly are part of this proposal. Transition monitoring is generally performed at cryogenic conditions by using temperature sensitive paint (TSP). To visualize laminar and turbulent areas a positive or negative temperature step has to be performed in a wind tunnel violating by nature the consistency of all flow parameters. New developments at ETW and DLR offer to overcome this deficit by innovative surface heating concepts which are proposed here for application. This approach will make temperature steps superfluous; hence, allow taking images during continuous incidence polars, the standard testing sequence in ETW

 Deliverables

List of deliverables.
Communication, Dissemination and exploitation Plan Other 2020-01-23 15:00:19

Take a look to the deliverables list in detail:  detailed list of BinCola deliverables.

Are you the coordinator (or a participant) of this project? Plaese send me more information about the "BINCOLA" project.

For instance: the website url (it has not provided by EU-opendata yet), the logo, a more detailed description of the project (in plain text as a rtf file or a word file), some pictures (as picture files, not embedded into any word file), twitter account, linkedin page, etc.

Send me an  email (fabio@fabiodisconzi.com) and I put them in your project's page as son as possible.

Thanks. And then put a link of this page into your project's website.

The information about "BINCOLA" are provided by the European Opendata Portal: CORDIS opendata.

More projects from the same programme (H2020-EU.3.4.5.4.)

WELTMAP (2019)

Wheel Lightweight Manufacturing Process

Read More  

ELADINE (2019)

Evaluation of LAminate composite Distortion by an Integrated Numerical-Experimental approach

Read More  

TREAL (2019)

Thermoplastic material allowable generation using a reliability-based virtual modeling platform

Read More