Opendata, web and dolomites

MicroMOUPE SIGNED

Microscopy - Making optimal use of photons and electrons

Total Cost €

0

EC-Contrib. €

0

Partnership

0

Views

0

 MicroMOUPE project word cloud

Explore the words cloud of the MicroMOUPE project. It provides you a very rough idea of what is the project "MicroMOUPE" about.

specimen    quadratic    probe    times    spatial    optimize    blanking    ponderomotive    particles    feasible    optically    limited    dna    correction    beam    cells    metal    pattern    accuracy    stanford    plate    modern    bright    shape    designed    university    tool    shot    technologically    detection    limits    proof    proteins    sensitivity    molecules    cavities    introducing    resolution    linear    post    self    imaging    evading    scattered    pulses    noise    demonstrated    created    electron    microscopes    nanoparticles    multiple    overcoming    switch    vienna    zernike    fundamental    interactions    optimal    microscopy    generator    signal    of    interact    landscapes    potentials    electro    intense    adaptive    arbitrary    photons    particle    aberration    experiment    free    coherent    enhancement    microscope    sensitive    fast    temporal    electrons    laser    nanometric    sub    specimens    creation    dark    optical    pass    limit    tested    optics    realized    single   

Project "MicroMOUPE" data sheet

The following table provides information about the project.

Coordinator
UNIVERSITAT WIEN 

Organization address
address: UNIVERSITATSRING 1
city: WIEN
postcode: 1010
website: www.univie.ac.at

contact info
title: n.a.
name: n.a.
surname: n.a.
function: n.a.
email: n.a.
telephone: n.a.
fax: n.a.

 Coordinator Country Austria [AT]
 Project website https://imaging.univie.ac.at/
 Total cost 1˙672˙752 €
 EC max contribution 1˙672˙752 € (100%)
 Programme 1. H2020-EU.1.1. (EXCELLENT SCIENCE - European Research Council (ERC))
 Code Call ERC-2017-STG
 Funding Scheme ERC-STG
 Starting year 2018
 Duration (year-month-day) from 2018-03-01   to  2023-02-28

 Partnership

Take a look of project's partnership.

# participants  country  role  EC contrib. [€] 
1    UNIVERSITAT WIEN AT (WIEN) coordinator 1˙672˙752.00

Map

 Project objective

The sensitivity of modern microscopy is limited by shot-noise. It limits the accuracy of measurements of specimen properties as well as the spatial resolution of electron microscopes when imaging sensitive specimens, such as proteins or DNA. But the shot-noise limit is not a fundamental limit. A technologically feasible and optimal approach to overcoming the shot-noise limit is to have each probe particle interact with the specimen multiple times. We recently introduced this concept to microscopy using self-imaging cavities. Within this project, I want to demonstrate post-selection free sub-shot noise microscopy with both photons and electrons. Optically this will be possible by introducing a fast electro-optical switch into a multi-pass microscope, evading the need for temporal post-selection. After this proof-of principle experiment, the sensitivity enhancement offered by multi-pass microscopy shall be applied to the detection of nanometric particles, such as single molecules, proteins and metal nanoparticles. Linear signal enhancement with the number of interactions is expected for bright-field microscopy. For dark-field microscopy a quadratic enhancement is expected, due to coherent build-up of scattered fields. Finally, adaptive optics will be used to optimize multi-pass microscopy for the study of cells. Multi-pass electron microscopy will be realized in collaboration with Stanford University. It will require several novel electron optical elements that will be designed and tested both at Stanford University and at the University of Vienna. One of these elements will be a pattern generator for electrons based on ponderomotive potentials. The required potential landscapes will be created using adaptive optics to shape intense laser pulses. With this novel electron optics tool fast beam-blanking, a phase plate for Zernike phase microscopy, arbitrary pattern creation and aberration correction will be demonstrated.

Are you the coordinator (or a participant) of this project? Plaese send me more information about the "MICROMOUPE" project.

For instance: the website url (it has not provided by EU-opendata yet), the logo, a more detailed description of the project (in plain text as a rtf file or a word file), some pictures (as picture files, not embedded into any word file), twitter account, linkedin page, etc.

Send me an  email (fabio@fabiodisconzi.com) and I put them in your project's page as son as possible.

Thanks. And then put a link of this page into your project's website.

The information about "MICROMOUPE" are provided by the European Opendata Portal: CORDIS opendata.

More projects from the same programme (H2020-EU.1.1.)

PonD (2019)

Particles-on-Demand for Multiscale Fluid Dynamics

Read More  

Regen-membrane (2019)

Pulsed Electrophoretic Deposition to give Membranes for Regenerative Medicine

Read More  

PEGASOS (2019)

Photon Emitting Gated Arrays for Scalable On-chip quantum Systems

Read More