Opendata, web and dolomites

MicroMOUPE SIGNED

Microscopy - Making optimal use of photons and electrons

Total Cost €

0

EC-Contrib. €

0

Partnership

0

Views

0

 MicroMOUPE project word cloud

Explore the words cloud of the MicroMOUPE project. It provides you a very rough idea of what is the project "MicroMOUPE" about.

microscopes    blanking    electron    sub    pass    free    enhancement    tested    switch    created    optically    particles    dark    interactions    creation    cells    coherent    multiple    landscapes    ponderomotive    specimens    microscopy    probe    detection    technologically    experiment    sensitivity    potentials    limited    quadratic    plate    limits    post    linear    nanometric    self    zernike    single    accuracy    sensitive    overcoming    of    bright    arbitrary    aberration    dna    stanford    nanoparticles    tool    electro    pattern    demonstrated    intense    shape    vienna    times    noise    modern    imaging    realized    photons    optimize    specimen    particle    electrons    resolution    proof    limit    introducing    cavities    microscope    university    laser    interact    optical    adaptive    molecules    feasible    shot    fast    optics    beam    proteins    signal    pulses    correction    temporal    spatial    generator    evading    metal    designed    scattered    optimal    fundamental   

Project "MicroMOUPE" data sheet

The following table provides information about the project.

Coordinator
UNIVERSITAT WIEN 

Organization address
address: UNIVERSITATSRING 1
city: WIEN
postcode: 1010
website: www.univie.ac.at

contact info
title: n.a.
name: n.a.
surname: n.a.
function: n.a.
email: n.a.
telephone: n.a.
fax: n.a.

 Coordinator Country Austria [AT]
 Project website https://imaging.univie.ac.at/
 Total cost 1˙672˙752 €
 EC max contribution 1˙672˙752 € (100%)
 Programme 1. H2020-EU.1.1. (EXCELLENT SCIENCE - European Research Council (ERC))
 Code Call ERC-2017-STG
 Funding Scheme ERC-STG
 Starting year 2018
 Duration (year-month-day) from 2018-03-01   to  2023-02-28

 Partnership

Take a look of project's partnership.

# participants  country  role  EC contrib. [€] 
1    UNIVERSITAT WIEN AT (WIEN) coordinator 1˙672˙752.00

Map

 Project objective

The sensitivity of modern microscopy is limited by shot-noise. It limits the accuracy of measurements of specimen properties as well as the spatial resolution of electron microscopes when imaging sensitive specimens, such as proteins or DNA. But the shot-noise limit is not a fundamental limit. A technologically feasible and optimal approach to overcoming the shot-noise limit is to have each probe particle interact with the specimen multiple times. We recently introduced this concept to microscopy using self-imaging cavities. Within this project, I want to demonstrate post-selection free sub-shot noise microscopy with both photons and electrons. Optically this will be possible by introducing a fast electro-optical switch into a multi-pass microscope, evading the need for temporal post-selection. After this proof-of principle experiment, the sensitivity enhancement offered by multi-pass microscopy shall be applied to the detection of nanometric particles, such as single molecules, proteins and metal nanoparticles. Linear signal enhancement with the number of interactions is expected for bright-field microscopy. For dark-field microscopy a quadratic enhancement is expected, due to coherent build-up of scattered fields. Finally, adaptive optics will be used to optimize multi-pass microscopy for the study of cells. Multi-pass electron microscopy will be realized in collaboration with Stanford University. It will require several novel electron optical elements that will be designed and tested both at Stanford University and at the University of Vienna. One of these elements will be a pattern generator for electrons based on ponderomotive potentials. The required potential landscapes will be created using adaptive optics to shape intense laser pulses. With this novel electron optics tool fast beam-blanking, a phase plate for Zernike phase microscopy, arbitrary pattern creation and aberration correction will be demonstrated.

Are you the coordinator (or a participant) of this project? Plaese send me more information about the "MICROMOUPE" project.

For instance: the website url (it has not provided by EU-opendata yet), the logo, a more detailed description of the project (in plain text as a rtf file or a word file), some pictures (as picture files, not embedded into any word file), twitter account, linkedin page, etc.

Send me an  email (fabio@fabiodisconzi.com) and I put them in your project's page as son as possible.

Thanks. And then put a link of this page into your project's website.

The information about "MICROMOUPE" are provided by the European Opendata Portal: CORDIS opendata.

More projects from the same programme (H2020-EU.1.1.)

PonD (2019)

Particles-on-Demand for Multiscale Fluid Dynamics

Read More  

Regen-membrane (2019)

Pulsed Electrophoretic Deposition to give Membranes for Regenerative Medicine

Read More  

Growth regulation (2019)

The wide-spread bacterial toxin delivery systems and their role in multicellularity

Read More