Opendata, web and dolomites

Sniff-Nose

A novel double-point intravascular diagnostic probe with continuous monitoring of the biomarker panel, dual oxygen tension PcvO2 and PcsO2, for clinical assessment of heart failure

Total Cost €

0

EC-Contrib. €

0

Partnership

0

Views

0

 Sniff-Nose project word cloud

Explore the words cloud of the Sniff-Nose project. It provides you a very rough idea of what is the project "Sniff-Nose" about.

heart    muscle    longer    annual    outside    2019    situation    biomarker    size    coronary    fluorescent    unmet    million    labs    customers    cava    metabolic    literature    panel    competing    geometry    utilise    vitro    inserted    resp    catheters    vascular    space    kimal    exist    minimise    probe    diagnostic    insertion    monitoring    trl    double    central    time    global    intermittent    2013    sheath    oxygenation    anaesthesiologists    positions    performed    curved    plc    tension    blood    645    solution    instead    rest    point    venous    nose    optical    abnormal    withdrawals    market    sniff       except    pcso2    dual    uk    saturation    single    oxygen    lower    returned    procedure    diameters    feasibility    cardiologists    sales    hundred    first    save    solutions    pcvo2    flows    continuous    intravascular    usability    returning    thousand    body    fiber    probes    oximetry    sinus    describes    vena    rate   

Project "Sniff-Nose" data sheet

The following table provides information about the project.

Coordinator
MI MEDICAL INNOVATION GMBH 

Organization address
address: ERTHALSTR. 12
city: ASCHAFFENBURG
postcode: 63739
website: n.a.

contact info
title: n.a.
name: n.a.
surname: n.a.
function: n.a.
email: n.a.
telephone: n.a.
fax: n.a.

 Coordinator Country Germany [DE]
 Project website http://www.mi-innovation.com
 Total cost 71˙429 €
 EC max contribution 50˙000 € (70%)
 Programme 1. H2020-EU.3.1.3. (Treating and managing disease)
 Code Call H2020-SMEINST-1-2015
 Funding Scheme SME-1
 Starting year 2015
 Duration (year-month-day) from 2015-09-01   to  2015-10-31

 Partnership

Take a look of project's partnership.

# participants  country  role  EC contrib. [€] 
1    MI MEDICAL INNOVATION GMBH DE (ASCHAFFENBURG) coordinator 50˙000.00

Map

 Project objective

Sniff-Nose shall sniff the oxygen tension resp. saturation of venous blood at two positions of a probe – with curved geometry to achieve that – in the Vena Cava (where all the returning blood of the body except of the heart flows) and in the Coronary Sinus (where the returned blood of the heart flows). As an abnormal metabolic situation of the heart muscle e.g. at heart failure will result in lower oxygen tension in the coronary sinus than in the rest of the body, the coronary sinus oxygen tension resp. saturation in comparison to the central venous oxygen tension resp. saturation is the biomarker for heart failure assessment. Our novel double-point intravascular diagnostic probe with continuous monitoring of the biomarker panel, dual oxygen tension PcvO2 and PcsO2, will utilise the state-of-the-art single optical fluorescent fiber technology to minimise geometry and size, to save the space in the probe and to achieve usability (instead of double fiber technology as in partially competing products for each measurement point) with outside diameters which can be inserted into the Vena Cava. The needs of the customers exist as literature describes procedure solutions to measure oxygenation at the two vascular positions, but these procedure solutions result in intermittent blood withdrawals through the insertion sheath from the Vena Cava with a longer time to results. Technical feasibility assessment of our Sniff Nose solution has been performed in-vitro in our labs, TRL 3. The Sniff-Nose dual-oximetry diagnostic probe market can be estimated from the central venous catheters market, with a global market of $645 million in 2013 and an annual growth rate of 4.9% through 2019. From the capabilities of our UK distribution partner Kimal plc we will solve the unmet needs of the cardiologists and anaesthesiologists, and achieve over the first 5 years sales of several hundred thousand probes.

Are you the coordinator (or a participant) of this project? Plaese send me more information about the "SNIFF-NOSE" project.

For instance: the website url (it has not provided by EU-opendata yet), the logo, a more detailed description of the project (in plain text as a rtf file or a word file), some pictures (as picture files, not embedded into any word file), twitter account, linkedin page, etc.

Send me an  email (fabio@fabiodisconzi.com) and I put them in your project's page as son as possible.

Thanks. And then put a link of this page into your project's website.

The information about "SNIFF-NOSE" are provided by the European Opendata Portal: CORDIS opendata.

More projects from the same programme (H2020-EU.3.1.3.)

TT4CL (2019)

Clinical development of oral oleylphosphocholine as a new drug for the treatment of Old World Cutaneous Leishmaniasis

Read More  

HELP (2019)

Collaboration for innovation: Establishment of a pan-nematode drug development platform

Read More  

HAP2 (2020)

Host-targeted Approaches for the Prevention and the treatment of Hospital-Acquired Pneumonia

Read More