Opendata, web and dolomites

MicroMOUPE SIGNED

Microscopy - Making optimal use of photons and electrons

Total Cost €

0

EC-Contrib. €

0

Partnership

0

Views

0

 MicroMOUPE project word cloud

Explore the words cloud of the MicroMOUPE project. It provides you a very rough idea of what is the project "MicroMOUPE" about.

demonstrated    coherent    intense    electron    created    bright    resolution    experiment    noise    beam    modern    microscopes    optically    electro    detection    specimen    dna    electrons    cavities    nanometric    multiple    quadratic    university    arbitrary    overcoming    proof    imaging    scattered    optics    laser    cells    designed    limited    accuracy    technologically    optimize    evading    introducing    realized    pulses    nanoparticles    generator    stanford    photons    particle    sensitive    signal    correction    probe    enhancement    vienna    of    metal    switch    zernike    fast    optimal    microscopy    microscope    shot    interactions    specimens    times    adaptive    aberration    optical    post    proteins    dark    self    tool    spatial    pattern    potentials    landscapes    linear    temporal    creation    feasible    molecules    interact    shape    single    plate    fundamental    sub    particles    limit    free    sensitivity    pass    limits    tested    blanking    ponderomotive   

Project "MicroMOUPE" data sheet

The following table provides information about the project.

Coordinator
UNIVERSITAT WIEN 

Organization address
address: UNIVERSITATSRING 1
city: WIEN
postcode: 1010
website: www.univie.ac.at

contact info
title: n.a.
name: n.a.
surname: n.a.
function: n.a.
email: n.a.
telephone: n.a.
fax: n.a.

 Coordinator Country Austria [AT]
 Project website https://imaging.univie.ac.at/
 Total cost 1˙672˙752 €
 EC max contribution 1˙672˙752 € (100%)
 Programme 1. H2020-EU.1.1. (EXCELLENT SCIENCE - European Research Council (ERC))
 Code Call ERC-2017-STG
 Funding Scheme ERC-STG
 Starting year 2018
 Duration (year-month-day) from 2018-03-01   to  2023-02-28

 Partnership

Take a look of project's partnership.

# participants  country  role  EC contrib. [€] 
1    UNIVERSITAT WIEN AT (WIEN) coordinator 1˙672˙752.00

Map

 Project objective

The sensitivity of modern microscopy is limited by shot-noise. It limits the accuracy of measurements of specimen properties as well as the spatial resolution of electron microscopes when imaging sensitive specimens, such as proteins or DNA. But the shot-noise limit is not a fundamental limit. A technologically feasible and optimal approach to overcoming the shot-noise limit is to have each probe particle interact with the specimen multiple times. We recently introduced this concept to microscopy using self-imaging cavities. Within this project, I want to demonstrate post-selection free sub-shot noise microscopy with both photons and electrons. Optically this will be possible by introducing a fast electro-optical switch into a multi-pass microscope, evading the need for temporal post-selection. After this proof-of principle experiment, the sensitivity enhancement offered by multi-pass microscopy shall be applied to the detection of nanometric particles, such as single molecules, proteins and metal nanoparticles. Linear signal enhancement with the number of interactions is expected for bright-field microscopy. For dark-field microscopy a quadratic enhancement is expected, due to coherent build-up of scattered fields. Finally, adaptive optics will be used to optimize multi-pass microscopy for the study of cells. Multi-pass electron microscopy will be realized in collaboration with Stanford University. It will require several novel electron optical elements that will be designed and tested both at Stanford University and at the University of Vienna. One of these elements will be a pattern generator for electrons based on ponderomotive potentials. The required potential landscapes will be created using adaptive optics to shape intense laser pulses. With this novel electron optics tool fast beam-blanking, a phase plate for Zernike phase microscopy, arbitrary pattern creation and aberration correction will be demonstrated.

Are you the coordinator (or a participant) of this project? Plaese send me more information about the "MICROMOUPE" project.

For instance: the website url (it has not provided by EU-opendata yet), the logo, a more detailed description of the project (in plain text as a rtf file or a word file), some pictures (as picture files, not embedded into any word file), twitter account, linkedin page, etc.

Send me an  email (fabio@fabiodisconzi.com) and I put them in your project's page as son as possible.

Thanks. And then put a link of this page into your project's website.

The information about "MICROMOUPE" are provided by the European Opendata Portal: CORDIS opendata.

More projects from the same programme (H2020-EU.1.1.)

PonD (2019)

Particles-on-Demand for Multiscale Fluid Dynamics

Read More  

Growth regulation (2019)

The wide-spread bacterial toxin delivery systems and their role in multicellularity

Read More  

REAL (2019)

Rights and Egalitarianism

Read More