Opendata, web and dolomites

MicroMOUPE SIGNED

Microscopy - Making optimal use of photons and electrons

Total Cost €

0

EC-Contrib. €

0

Partnership

0

Views

0

 MicroMOUPE project word cloud

Explore the words cloud of the MicroMOUPE project. It provides you a very rough idea of what is the project "MicroMOUPE" about.

probe    pattern    shape    tested    pass    nanometric    electron    signal    resolution    landscapes    post    interactions    limited    proof    fundamental    intense    electro    laser    evading    modern    particles    spatial    technologically    temporal    ponderomotive    free    multiple    quadratic    linear    realized    zernike    optically    tool    dna    sensitivity    metal    single    correction    microscopy    imaging    scattered    aberration    shot    beam    switch    adaptive    particle    proteins    photons    noise    overcoming    feasible    detection    sensitive    blanking    coherent    bright    stanford    sub    microscopes    limit    specimens    cells    optimize    introducing    interact    microscope    designed    dark    plate    vienna    times    optics    experiment    cavities    optical    limits    optimal    molecules    accuracy    created    nanoparticles    pulses    enhancement    potentials    fast    specimen    demonstrated    self    arbitrary    generator    creation    university    of    electrons   

Project "MicroMOUPE" data sheet

The following table provides information about the project.

Coordinator
UNIVERSITAT WIEN 

Organization address
address: UNIVERSITATSRING 1
city: WIEN
postcode: 1010
website: www.univie.ac.at

contact info
title: n.a.
name: n.a.
surname: n.a.
function: n.a.
email: n.a.
telephone: n.a.
fax: n.a.

 Coordinator Country Austria [AT]
 Project website https://imaging.univie.ac.at/
 Total cost 1˙672˙752 €
 EC max contribution 1˙672˙752 € (100%)
 Programme 1. H2020-EU.1.1. (EXCELLENT SCIENCE - European Research Council (ERC))
 Code Call ERC-2017-STG
 Funding Scheme ERC-STG
 Starting year 2018
 Duration (year-month-day) from 2018-03-01   to  2023-02-28

 Partnership

Take a look of project's partnership.

# participants  country  role  EC contrib. [€] 
1    UNIVERSITAT WIEN AT (WIEN) coordinator 1˙672˙752.00

Map

 Project objective

The sensitivity of modern microscopy is limited by shot-noise. It limits the accuracy of measurements of specimen properties as well as the spatial resolution of electron microscopes when imaging sensitive specimens, such as proteins or DNA. But the shot-noise limit is not a fundamental limit. A technologically feasible and optimal approach to overcoming the shot-noise limit is to have each probe particle interact with the specimen multiple times. We recently introduced this concept to microscopy using self-imaging cavities. Within this project, I want to demonstrate post-selection free sub-shot noise microscopy with both photons and electrons. Optically this will be possible by introducing a fast electro-optical switch into a multi-pass microscope, evading the need for temporal post-selection. After this proof-of principle experiment, the sensitivity enhancement offered by multi-pass microscopy shall be applied to the detection of nanometric particles, such as single molecules, proteins and metal nanoparticles. Linear signal enhancement with the number of interactions is expected for bright-field microscopy. For dark-field microscopy a quadratic enhancement is expected, due to coherent build-up of scattered fields. Finally, adaptive optics will be used to optimize multi-pass microscopy for the study of cells. Multi-pass electron microscopy will be realized in collaboration with Stanford University. It will require several novel electron optical elements that will be designed and tested both at Stanford University and at the University of Vienna. One of these elements will be a pattern generator for electrons based on ponderomotive potentials. The required potential landscapes will be created using adaptive optics to shape intense laser pulses. With this novel electron optics tool fast beam-blanking, a phase plate for Zernike phase microscopy, arbitrary pattern creation and aberration correction will be demonstrated.

Are you the coordinator (or a participant) of this project? Plaese send me more information about the "MICROMOUPE" project.

For instance: the website url (it has not provided by EU-opendata yet), the logo, a more detailed description of the project (in plain text as a rtf file or a word file), some pictures (as picture files, not embedded into any word file), twitter account, linkedin page, etc.

Send me an  email (fabio@fabiodisconzi.com) and I put them in your project's page as son as possible.

Thanks. And then put a link of this page into your project's website.

The information about "MICROMOUPE" are provided by the European Opendata Portal: CORDIS opendata.

More projects from the same programme (H2020-EU.1.1.)

PonD (2019)

Particles-on-Demand for Multiscale Fluid Dynamics

Read More  

Growth regulation (2019)

The wide-spread bacterial toxin delivery systems and their role in multicellularity

Read More  

Aware (2019)

Aiding Antibiotic Development with Deep Analysis of Resistance Evolution

Read More