GENiC

Globally optimized ENergy efficient data Centres - GENiC

 Coordinatore CORK INSTITUTE OF TECHNOLOGY 

 Organization address address: ROSSA AVENUE, BISHOPSTOWN
city: CORK

contact info
Titolo: Dr.
Nome: Dirk
Cognome: Pesch
Email: send email
Telefono: +353 214335566
Fax: +353 21 4335561

 Nazionalità Coordinatore Ireland [IE]
 Totale costo 5˙417˙047 €
 EC contributo 3˙274˙522 €
 Programma FP7-ICT
Specific Programme "Cooperation": Information and communication technologies
 Code Call FP7-SMARTCITIES-2013
 Funding Scheme CP
 Anno di inizio 2013
 Periodo (anno-mese-giorno) 2013-10-01   -   2016-09-30

 Partecipanti

# participant  country  role  EC contrib. [€] 
1    CORK INSTITUTE OF TECHNOLOGY

 Organization address address: ROSSA AVENUE, BISHOPSTOWN
city: CORK

contact info
Titolo: Dr.
Nome: Dirk
Cognome: Pesch
Email: send email
Telefono: +353 214335566
Fax: +353 21 4335561

IE (CORK) coordinator 0.00
2    ACCIONA INFRAESTRUCTURAS S.A.

 Organization address address: AVENIDA DE EUROPA
city: ALCOBENDAS
postcode: 28108

contact info
Titolo: Mr.
Nome: Miguel Angel
Cognome: Paris Torres
Email: send email
Telefono: 34917912020
Fax: 34917912101

ES (ALCOBENDAS) participant 0.00
3    ATOS SPAIN SA

 Organization address address: Calle de Albarracin
city: Madrid
postcode: 28037

contact info
Titolo: Mrs.
Nome: Clara
Cognome: Pezuela
Email: send email
Telefono: +34 912148609
Fax: +34 917543252

ES (Madrid) participant 0.00
4    IBM RESEARCH GMBH

 Organization address address: SAEUMERSTRASSE
city: RUESCHLIKON
postcode: 8803

contact info
Titolo: Ms.
Nome: Catherine
Cognome: Trachsel
Email: send email
Telefono: +41 44 724 8289

CH (RUESCHLIKON) participant 0.00
5    TECHNISCHE UNIVERSITEIT EINDHOVEN

 Organization address address: DEN DOLECH
city: EINDHOVEN
postcode: 5612 AZ

contact info
Titolo: Dr.
Nome: Paul
Cognome: Scholte
Email: send email
Telefono: +31 40 247 3970
Fax: +31 40 245 2432

NL (EINDHOVEN) participant 0.00
6    UNITED TECHNOLOGIES RESEARCH CENTRE IRELAND, LIMITED

 Organization address address: FOURTH FLOOR, PENROSE BUSINESS CENTER, PENROSE WHARF, PENROS
city: CORK
postcode: -

contact info
Titolo: Mr.
Nome: Andrew
Cognome: O'Leary
Email: send email
Telefono: +353 214508442

IE (CORK) participant 0.00
7    UNIVERSITY COLLEGE CORK, NATIONAL UNIVERSITY OF IRELAND, CORK

 Organization address address: Western Road
city: CORK
postcode: -

contact info
Titolo: Dr.
Nome: David
Cognome: O'Connell
Email: send email
Telefono: +353 214903501

IE (CORK) participant 0.00

Mappa


 Word cloud

Esplora la "nuvola delle parole (Word Cloud) per avere un'idea di massima del progetto.

sources    genic    computing    storage    energy    renewable    server    power    generation    platform    dc    heat    integration    waste    fans    cooling    air    consumption    temperature    local    computation    controls    optimisation    data    recovery    racks    consumes   

 Obiettivo del progetto (Objective)

Data Centre (DC) energy consumption has doubled between 2000 and 2005 and grew by 50% from 2005 to 2010 consuming 1.5% of global energy with continued rapid growth. On average, computing consumes 60% of total energy while cooling consumes 35%. While new technology can lead to a 40% reduction computation and cooling typically operate without coordination or optimization. While server energy management can reduce energy use at CPU, rack, and DC level dynamic computation scheduling is not integrated with sensing and cooling. DC cooling typically operates at constant cold air temperature to protect the hottest server racks while local fans distribute the temperature across racks. However, these local server controls are not integrated with room cooling systems so it is not possible to optimize chiller, air fans and server fans as a system. The integration of renewable energy sources (RES) has received limited interest from the DC community due to lack of interoperability of generation, storage and heat recovery and installation and maintenance cost versus payback. The adoption of new technologies related to computing, cooling, generation, energy storage, and waste heat recovery individually requires sophisticated controls, but no single manufacturer provides a complete system so integration between control systems does not exist. To address this, GENiC will develop an integrated management and control platform for DC wide optimisation of energy consumption by integrating monitoring and control of computation, data storage, cooling, local power generation, energy storage, and waste heat recovery. The platform will include open interfaces, common data formats, control and optimisation functions and decision support to achieve a substantial reduction in energy consumption, PUE, CUE. GENiC will develop a process and tool chain for cost-effective integration of renewable energy sources into DC power systems demonstrating renewable energy penetration in excess of 80%.

Altri progetti dello stesso programma (FP7-ICT)

COMET (2010)

COntent Mediator architecture for content-aware nETworks

Read More  

DISCUS (2012)

The DIStributed Core for unlimited bandwidth supply for all Users and Services

Read More  

HURRICANE (2008)

Handovers for Ubiquitous and optimal bRoadband connectIvity among CooperAtive Networking Environments

Read More