Opendata, web and dolomites

DiaMon

Continuous Diaphragm Monitoring for mechanically ventilated patients

Total Cost €

0

EC-Contrib. €

0

Partnership

0

Views

0

 DiaMon project word cloud

Explore the words cloud of the DiaMon project. It provides you a very rough idea of what is the project "DiaMon" about.

reduce    periods    turnover    500    innovative    healthcare    staff    tracheal    baro    care    extubation    37    provides    significantly    mv    pneumonia    patient    monitoring    consume    manual    annually    billion    diamon    expertise    ventilation    prolonged    103    estimation    diaphragm    market    substantially    tool    critical    days    put    day    35    leverage    expensive    movement    phases    icu    interventions    safe    recovery    mechanical    direct    2025    optimise    weakness    accomplishment    volutrauma    quality    complications    15    global    ventilated    adjustment       extended       efficient    treatment    expenditure    hospital    interaction    continuous    benefits    stenosis    small    icus    patients    timing    precise    respinor    procedure    intensive    diagnostic    demand    time    back    operation    flexible    cumulated    medical       us    million    enormous    ultrasound    extubated    competence    failures    atrophy    sensor    muscle    ventilator   

Project "DiaMon" data sheet

The following table provides information about the project.

Coordinator
RESPINOR AS 

Organization address
address: GAUSTADALLEEN 21
city: OSLO
postcode: 349
website: n.a.

contact info
title: n.a.
name: n.a.
surname: n.a.
function: n.a.
email: n.a.
telephone: n.a.
fax: n.a.

 Coordinator Country Norway [NO]
 Project website http://www.respinor.com
 Total cost 71˙429 €
 EC max contribution 50˙000 € (70%)
 Programme 1. H2020-EU.3.1.3. (Treating and managing disease)
 Code Call H2020-SMEINST-1-2015
 Funding Scheme SME-1
 Starting year 2016
 Duration (year-month-day) from 2016-03-01   to  2016-08-31

 Partnership

Take a look of project's partnership.

# participants  country  role  EC contrib. [€] 
1    RESPINOR AS NO (OSLO) coordinator 50˙000.00

Map

 Project objective

Mechanical ventilation (MV) is one of the most common interventions implemented in the intensive care unit (ICU). MV is associated with a number of complications such as atrophy, muscle weakness, pneumonia, tracheal stenosis and baro/volutrauma. Complications increase in likelihood with duration of ventilation, and studies show that 15% of the patients that are extubated must be put back on mechanical ventilation for extended treatment. Timing and adjustment of MV is therefore critical to ensure safe recovery. MV has enormous costs for healthcare systems with US$1,500 per patient per day. MV patients in ICUs account for 6% of all ventilated patients but consume 37% of ICU resources. With an estimation of 1.35 million MV patients in the EU for an average of 4-5 days, this represents the enormous expenditure of US$3.3 billion (€3.1 billion) annually. Respinor has developed a novel, small and flexible ultrasound sensor (DiaMon) that provides precise, continuous information on diaphragm movement over prolonged periods of time without the need of direct manual operation or expertise monitoring. The information from DiaMon will enable ICUs staff to optimise the interaction between patients and the mechanical ventilator, reduce ventilation time, and significantly reduce extubation failures. With DiaMon, Respinor targets ICUs to offer a cost-efficient and innovative diagnostic tool that will substantially improve an expensive and critical medical procedure that is common – and increasingly growing in demand - in the global hospital healthcare market. The accomplishment of the project objectives (Phases 1 and 2) will bring major benefits to Respinor with a cumulated turnover of 103 million € in 2025 in the mechanical ventilation market. DiaMon will furthermore greatly improve quality of treatment for ventilation patients, substantially reduce costs in ICUs, and leverage competence in mechanical ventilation treatment.

Are you the coordinator (or a participant) of this project? Plaese send me more information about the "DIAMON" project.

For instance: the website url (it has not provided by EU-opendata yet), the logo, a more detailed description of the project (in plain text as a rtf file or a word file), some pictures (as picture files, not embedded into any word file), twitter account, linkedin page, etc.

Send me an  email (fabio@fabiodisconzi.com) and I put them in your project's page as son as possible.

Thanks. And then put a link of this page into your project's website.

The information about "DIAMON" are provided by the European Opendata Portal: CORDIS opendata.

More projects from the same programme (H2020-EU.3.1.3.)

TT4CL (2019)

Clinical development of oral oleylphosphocholine as a new drug for the treatment of Old World Cutaneous Leishmaniasis

Read More  

INTE-AFRICA (2019)

Integrating and decentralising diabetes and hypertension services in Africa

Read More  

PREFERABLE (2019)

Project on Exercise for Fatigue Eradication in Advanced Breast cancer to improve quality of life

Read More