Opendata, web and dolomites

HandheldOCT SIGNED

Handheld optical coherence tomography

Total Cost €

0

EC-Contrib. €

0

Partnership

0

Views

0

 HandheldOCT project word cloud

Explore the words cloud of the HandheldOCT project. It provides you a very rough idea of what is the project "HandheldOCT" about.

wavelength    imaging    manufacturer    smaller    solid    akinetic    health    4x    clinical    size    age    reduce    translational    children    mainly    semiconductor    10x    specifications    vivo    invasive    diagnostically    region    proof    5x    endeavour    circuit    world    handheldoct    small    therapy    implementing    laser    diagnosis    silicon    technique    place    existence    elderly    electronics    retinal    requirement    limitations    outcome    cheaper    care    faster    variety    clinicians    source    monolithic    1060nm    photonics    nitride    packaging    patient    solution    mobile    performance    companies    integration    usability    sources    optimum    combined    healthcare    remote    handheld    speed    disease    micro    significantly    bedridden    made    revolutionizing    diagnostics    hybrid    foundry    photonic    coherence    home    expertise    pathologies    swept    born    tomography    medical    oct    sight    penetration    diagnostic    leverage    3d    point    germanium    waveguides    ophthalmic    photodiodes    compact    cohort    biopsy    threatening    miniaturized    generation    ophthalmology    tissue    off    optical    mostly    primarily    adoption    optics    proven   

Project "HandheldOCT" data sheet

The following table provides information about the project.

Coordinator
MEDIZINISCHE UNIVERSITAET WIEN 

Organization address
address: SPITALGASSE 23
city: WIEN
postcode: 1090
website: www.meduniwien.ac.at

contact info
title: n.a.
name: n.a.
surname: n.a.
function: n.a.
email: n.a.
telephone: n.a.
fax: n.a.

 Coordinator Country Austria [AT]
 Total cost 5˙985˙978 €
 EC max contribution 5˙985˙978 € (100%)
 Programme 1. H2020-EU.2.1.1. (INDUSTRIAL LEADERSHIP - Leadership in enabling and industrial technologies - Information and Communication Technologies (ICT))
 Code Call H2020-ICT-2019-2
 Funding Scheme RIA
 Starting year 2020
 Duration (year-month-day) from 2020-01-01   to  2024-12-31

 Partnership

Take a look of project's partnership.

# participants  country  role  EC contrib. [€] 
1    MEDIZINISCHE UNIVERSITAET WIEN AT (WIEN) coordinator 786˙820.00
2    INTERUNIVERSITAIR MICRO-ELECTRONICA CENTRUM BE (LEUVEN) participant 1˙600˙751.00
3    CARL ZEISS AG DE (OBERKOCHEN) participant 995˙060.00
4    INNOLUME GMBH DE (DORTMUND) participant 933˙750.00
5    AIT AUSTRIAN INSTITUTE OF TECHNOLOGY GMBH AT (WIEN) participant 723˙278.00
6    UNIVERSITY COLLEGE CORK - NATIONAL UNIVERSITY OF IRELAND, CORK IE (Cork) participant 592˙567.00
7    NANOSCRIBE GMBH DE (EGGENSTEIN-LEOPOLDSHAFEN) participant 353˙751.00

Map

 Project objective

Optical coherence tomography (OCT) is a revolutionizing in-vivo 3D imaging technique for non-invasive optical biopsy addressing medical needs in early diagnosis and effective disease management. OCT has proven its value primarily in ophthalmology but more recently also in a variety of other medical fields. However, wide adoption in health care, a requirement for effective therapy control, has not taken place mainly due to cost limitations and the non-existence of miniaturized mobile devices. Integrated photonics is expected to leverage off many advances made in integrated electronics. Based on photonic integrated circuit technology, HandheldOCT will enable a new generation of handheld OCT systems in the 1060nm wavelength region for optimum tissue penetration with step-changes in imaging performance (4x faster imaging speed), with size (10x smaller) and cost (2-5x cheaper) beyond state-of-the-art. The monolithic integration of silicon nitride optical waveguides, Germanium photodiodes, and micro-optics combined with the hybrid integration of a novel compact all-semiconductor akinetic swept source will enable a mobile, low-cost solution of high usability. HandheldOCT is expected to contribute significantly to a widespread adoption of OCT in point-of-care diagnostics (e.g. for new-born, children, bedridden elderly, home remote diagnosis) and for diagnostic-driven therapy of major sight-threatening, mostly age-related retinal pathologies with the aim to improve patient outcome and reduce healthcare costs. The endeavour is strongly driven by companies and research organisations with solid expertise in silicon foundry technology, miniaturized laser sources, photonic design and packaging, electronics, and medical OCT system integration. The consortium includes clinicians and the world-leading ophthalmic equipment manufacturer focusing on implementing diagnostically relevant specifications and the translational clinical proof-of-principle testing on a small patient cohort.

Are you the coordinator (or a participant) of this project? Plaese send me more information about the "HANDHELDOCT" project.

For instance: the website url (it has not provided by EU-opendata yet), the logo, a more detailed description of the project (in plain text as a rtf file or a word file), some pictures (as picture files, not embedded into any word file), twitter account, linkedin page, etc.

Send me an  email (fabio@fabiodisconzi.com) and I put them in your project's page as son as possible.

Thanks. And then put a link of this page into your project's website.

The information about "HANDHELDOCT" are provided by the European Opendata Portal: CORDIS opendata.

More projects from the same programme (H2020-EU.2.1.1.)

5E (2019)

Federating European Electronics Ecosystems for Competitive Electronics Industries

Read More  

NEoteRIC (2020)

NEuromorphic Reconfigurable Integrated photonic Circuits as artificial image processor

Read More  

WINTHER (2020)

Fast optoacoustic mesoscopy, using the skin as a window for therapeutic monitoring of local and systemic disease.

Read More